Sample Record for 2020-05-13-33
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213485 DEA: 032F9804 EFIS: 0312000026
QA Service Level: 1
DIST-CO-RTE-PM: 03-COL-20-31.7/32.9
Work Description: PAVEMENT REHABILITATION
Location Description: COLUSA COUNTY IN AND NEAR COLUSA FROM 0.1 MILE EAST OF THE MARKET STREET/STATE ROUTE 20 INTERSECTION TO 0.1 MILE SOUTH OF BUTTE VISTA DRIVE
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 24207 County Road 100A, Davis CA 95617
Resident Engineer: Anthony Granados Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2020-05-13-33
TL Number from the TL Form:
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 05/13/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2020
The quantity of what the sample constitutes: 3 bags
A brief description of the sample: 3/4 cold feed and rap
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Hallwood
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-58-0006::HALLWOOD PLANT
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Agg sampler at drum plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 11
DIME Test ID: 2020-05-13-33-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/17/2020
Date Tested: 06/02/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
0 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
0 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
98 %
|
Cumulative percent passing the 1/2 in. sieve
|
87 %
|
Cumulative percent passing the 3/8 in. sieve
|
71 %
|
Cumulative percent passing the #4 sieve
|
52 %
|
Cumulative percent passing the #8 sieve
|
37 %
|
Cumulative percent passing the #16 sieve
|
24 %
|
Cumulative percent passing the #30 sieve
|
16 %
|
Cumulative percent passing the #50 sieve
|
11 %
|
Cumulative percent passing the #100 sieve
|
7 %
|
Cumulative percent passing the #200 sieve
|
4.2 %
|
Test 2 of 11
DIME Test ID: 2020-05-13-33-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 07/17/2020
Date Tested: 05/20/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: Raw RAP grading
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
0 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
0 %
|
Cumulative percent passing the 1 in. sieve
|
0 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
96 %
|
Cumulative percent passing the 3/8 in. sieve
|
87 %
|
Cumulative percent passing the #4 sieve
|
58 %
|
Cumulative percent passing the #8 sieve
|
41 %
|
Cumulative percent passing the #16 sieve
|
31 %
|
Cumulative percent passing the #30 sieve
|
23 %
|
Cumulative percent passing the #50 sieve
|
17 %
|
Cumulative percent passing the #100 sieve
|
12 %
|
Cumulative percent passing the #200 sieve
|
8.9 %
|
Test 3 of 11
DIME Test ID: 2020-05-13-33-3
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 07/17/2020
Date Tested: 06/08/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method
|
2 - Individual Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 1 Faced
|
Weighted average percentage of fractured, coarse, 1 faced particles
|
96 %
|
Test 4 of 11
DIME Test ID: 2020-05-13-33-4
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 07/17/2020
Date Tested: 06/08/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method
|
2 - Individual Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 2 Faced
|
Weighted average percentage of fractured, coarse, 2 faced particles
|
91 %
|
Test 5 of 11
DIME Test ID: 2020-05-13-33-5
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 07/17/2020
Date Tested: 06/03/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method
|
2 - Individual Fracture Determination
|
Aggregate Size and Fracture Type
|
Fine 1 Faced
|
Percentage of fractured, fine, 1 faced particles tested
|
99 %
|
Test 6 of 11
DIME Test ID: 2020-05-13-33-6
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 07/17/2020
Date Tested: 06/09/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation
|
C
|
Percent loss after 100 revolutions
|
3 %
|
Percent loss after 500 revolutions
|
16 %
|
Test 7 of 11
DIME Test ID: 2020-05-13-33-7
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 07/17/2020
Date Tested: 06/02/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 8 of 11
DIME Test ID: 2020-05-13-33-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 07/17/2020
Date Tested: 06/02/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed?
|
Method A
|
Bulk dry specific gravity
|
2.712
|
Average uncompacted voids
|
47.9 %
|
Test 9 of 11
DIME Test ID: 2020-05-13-33-9
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 07/17/2020
Date Tested: 06/02/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing
|
Bulk
|
Specific Gravity
|
2.774
|
Absorption
|
0.8 %
|
Test 10 of 11
DIME Test ID: 2020-05-13-33-10
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 07/17/2020
Date Tested: 06/02/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity
|
2.712
|
Bulk specific gravity (SSD Basis)
|
2.750
|
Apparent specific gravity
|
2.819
|
Absorption
|
1.4 %
|
Test 11 of 11
DIME Test ID: 2020-05-13-33-11
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/17/2020
Date Tested: 06/01/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.579
|
Theoretical maximum density at 25°C (77°F)
|
no data
|