Sample Record for 2020-07-15-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214601 DEA: 041J5694 EFIS: 0419000313
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0/21.8
Work Description: San Mateo US 101 Express Lanes North
Location Description:
Contractor Name: KIEWIT INFRASTRUCTURE COMPANY
Contractor Address: 1301 SHOREWAY RD, SUITE 275, BELMONT, CA 94402
Resident Engineer: Douglas Inori Structure Rep.: Tyler Pinell
Sample Information
DIME Sample ID: 2020-07-15-6
TL Number from the TL Form:
Sample Submitted By Organization: CT METS QASI - Los Angeles Design Build Field Laboratory
Sample Organization Contact: (619) 204-7248
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/15/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2020
The quantity of what the sample constitutes: 20 pcs
A brief description of the sample: ASTM A325 1-1/4"x 4" Bolt
From where was the sample collected: Source
Laboratory sample identification: L149-073-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Structural and Steel Products
Material Information
Rocap Number(s): 060920DR
Heat Number(s): Bolt 100793373, Nut DL17100198, Washer 4171854
Nut Mfg. Lot Number(s): 388517A
Washer Mfg. Lot Number(s): D7043
Bolt Specification: ASTM A325
Bolt Length(s): 4"
Nut Specification: ASTM A563
Washer Specification: ASTM F436
Finish: Mech.Zinc Galv. ASTM B695
Diameter/Size: 1-1/4"x 4"
Bolt Mfg. Lot Number: 421045A
Rocap Test Requirement(s): 060920DR
Lubricant Requirements(s): Yes
Test Results
Test 1 of 7
DIME Test ID: 2020-07-15-6-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Bolt
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 4A | 421045A | 1.2500 | 140754 | 626.1 | 6.00 | A325 Bolt | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
no data
|
Test 2 of 7
DIME Test ID: 2020-07-15-6-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/19/2020
Date Tested: 08/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
421045A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 N USA
|
Size
|
1.250 in
|
Bolt Length
|
4 in
|
Gage Type
|
Pass
|
Test 3 of 7
DIME Test ID: 2020-07-15-6-3
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/19/2020
Date Tested: 08/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
388517A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
1.250 in
|
Gage Type
|
Pass
|
Test 4 of 7
DIME Test ID: 2020-07-15-6-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/19/2020
Date Tested: 08/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
421045A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 N USA
|
Size
|
1.250 in
|
Bolt Length
|
4 in
|
Measurement Average
|
3.29 mils
|
Test 5 of 7
DIME Test ID: 2020-07-15-6-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/19/2020
Date Tested: 08/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
388517A
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
DH N
|
Size
|
1.250 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.06 mils
|
Test 6 of 7
DIME Test ID: 2020-07-15-6-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/19/2020
Date Tested: 08/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7043
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
P F436
|
Size
|
1.250 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.33 mils
|
Test 7 of 7
DIME Test ID: 2020-07-15-6-7
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 08/19/2020
Date Tested: 08/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7043
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
P F436
|
Size
|
1.250 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.25
|
Spacing
|
Ok
|