Sample Record for 2020-07-06-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214228 DEA: 120N4904 EFIS: 1214000050
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-91-R12.5/R13.9
Work Description: VEHICLE ENFORCEMENT FACILITY IMPROVEMENT AT PERALTA WEIGH STATION.
Location Description: ORANGE COUNTY IN ANAHEIM FROM 1.0 MILE EAST OF ROUTE 91/90 SEPARATION TO 0.5 MILE WEST OF WEIR CANYON ROAD UNDERCROSSING
Contractor Name: SPECTRUM CONSTRUCTION GROUP, INC.
Contractor Address: 32 EDELMAN, IRVINE, CA 92618
Resident Engineer: Dat Pham Structure Rep.: Bijan Ronagh-Langroodi
Sample Information
DIME Sample ID: 2020-07-06-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/06/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/10/2020
The quantity of what the sample constitutes: 23
A brief description of the sample: ASTM F1554 Gr 36 no headed anchor bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bristol Machine
Material Information
Rocap Number(s): N/A
Heat Number(s): 1202009463
Nut Mfg. Lot Number(s): 31074-71079609
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM F1554 Gr 36
Bolt Length(s): 31-3/4”
Nut Specification: ASTM A563 Gr. DH
Washer Specification: ASTM A36
Finish: Black
Diameter/Size: 1-1/4”
Bolt Mfg. Lot Number: 120200946323
Rocap Test Requirement(s): None
Lubricant Requirements(s): None
Test Results
Test 1 of 5
DIME Test ID: 2020-07-06-6-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 07/23/2020
Date Tested: 07/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 1202009463 | 0.499 | 0.196 | 53771 | 76284 | 31.8 | fsaylor |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
Test 2 of 5
DIME Test ID: 2020-07-06-6-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 07/23/2020
Date Tested: 07/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 1202009463 | 0.498 | 0.195 | 55743 | 76223 | 32.7 | fsaylor |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
Test 3 of 5
DIME Test ID: 2020-07-06-6-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 07/23/2020
Date Tested: 07/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
1202009463
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain
|
Product Markings
|
BLUE PAINT
|
Size
|
1.250 in
|
Bolt Length
|
31.75 in
|
Gage Type
|
Pass
|
Test 4 of 5
DIME Test ID: 2020-07-06-6-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 07/23/2020
Date Tested: 07/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
31074-71079609
|
Finish Coating
|
Plain
|
Product Markings
|
U DH
|
Size
|
1.250 in
|
Gage Type
|
Pass
|
Test 5 of 5
DIME Test ID: 2020-07-06-6-5
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 07/23/2020
Date Tested: 07/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
31074-71079609
|
Finish Coating
|
Plain
|
Product Markings
|
U DH
|
Size
|
1.250 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
32.02
|
Spacing
|
Ok
|