Print Report | Back to Sample Detail

Sample Record for 2020-05-27-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66666 DEA: APP EFIS: 0019000052 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-05-27-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Sample Organization Contact: (916) 227-7204
Type of Sample: Aggregate Prequalification Program
Type of Material: Aggregate
Sample Taken Date: 05/27/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/27/2020
The quantity of what the sample constitutes: 150 lbs
A brief description of the sample: Washed Concrete Sand WCS
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials Company - Palmdale

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0020::PALMDALE
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Stockpile @ Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: fine
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2020-05-27-27-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates07/03/202007/03/2020Francisco RomeroCT D08 - Fontana Southern Regional LaboratoryAPP Material is being shipped to your lab for QA testing. Please perform testing after receipt of material. Thank you, APP Administrator.
2020-05-27-27-2CTM 213-December 2012: Method of Test for Organic Impurities in Concrete Sand07/03/202007/03/2020Francisco RomeroCT D08 - Fontana Southern Regional LaboratoryAPP material is being shipped to your lab for QA testing. Please perform testing after receipt of material. Thank you, APP Administrator.
2020-05-27-27-3CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate07/03/202007/03/2020Francisco RomeroCT D08 - Fontana Southern Regional LaboratoryAPP material is being shipped to your lab for QA testing. Please perform testing after receipt of material. Thank you, APP Administrator.
2020-05-27-27-4CTM 217-June 2011: Method of Test for Sand Equivalent07/03/202007/03/2020Francisco RomeroCT D08 - Fontana Southern Regional LaboratoryAPP material is being shipped to your lab for QA testing. Please perform testing after receipt of material. Thank you, APP Administrator.
2020-05-27-27-5CTM 229-June 2011: Method of Test for Durability Index07/03/202007/03/2020Francisco RomeroCT D08 - Fontana Southern Regional LaboratoryAPP material is being shipped to your lab for QA testing. Please perform testing after receipt of material. Thank you, APP Administrator.