Print Report | Back to Sample Detail

Sample Record for 2020-05-04-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214516 DEA: 024H2404 EFIS: 0218000098 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-32.0/38.0,53.7/63.8
Work Description: PLACE HMA (TYPE A) OVERLAY, SHOULDER BACKING, AND TRAFFIC STRIPE.
Location Description: TRINITY COUNTY NEAR WEAVERVILLE FROM 0.4 MILE NORTH OF BROWNS RANCH ROAD TO 0.1 MILE NORTH OF RUSH CREEK ROAD AND FROM EAST FORK STUART BRIDGE TO 2.4 MILES NORTH OF EL DORADO WAY
Contractor Name: TULLIS, INC.
Contractor Address: 16951 CLEAR CREEK RD, REDDING CA 96001
Resident Engineer: Mandhir Grewal Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-05-04-31
TL Number from the TL Form: 002553
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 05/04/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/04/2020
The quantity of what the sample constitutes: Up to Five Days Paving
A brief description of the sample: 1/2-inch Type A Treated Virgin Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: D78417A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Northstate Asphalt, Redding, CA

Material Information

Source Identification (SMARA or name of Pit): 91-45-0057
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Cold Feed
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: JMF 19-11-P
Lot number: Unknown
Sublot number: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2020-05-04-31-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 06/22/2020
Date Tested: 05/06/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive, MS-83,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type) Yes
Total mass of material in the sample 4230 grams
Cumulative mass retained on the 1 1/2 in. sieve 0 grams
Cumulative mass retained on the 1 in. sieve 0 grams
Cumulative mass retained on the 3/4 in. sieve 0 grams
Cumulative mass retained on the 1/2 in. sieve 268 grams
Cumulative mass retained on the 3/8 in. sieve 707 grams
Mass retained on the 1/4 in. sieve 1372 grams
Cumulative mass retained on the #4 sieve 1779 grams
Total sample mass passing the #4 sieve 2451 grams
Total mass of fine material in the sample 516.9 grams
Cumulative mass retained on the #8 sieve 188.6 grams
Cumulative mass retained on the #16 sieve 298.4 grams
Cumulative mass retained on the #30 sieve 368 grams
Cumulative mass retained on the #50 sieve 413.5 grams
Cumulative mass retained on the #100 sieve 443.5 grams
Cumulative mass retained on the #200 sieve 461 grams
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 93.7 %
Cumulative percent passing the 3/8 in. sieve 83.3 %
Cumulative percent passing the 1/4 in. sieve 67.6 %
Cumulative percent passing the #4 sieve 57.9 %
Cumulative percent passing the #8 sieve 36.8 %
Cumulative percent passing the #16 sieve 24.5 %
Cumulative percent passing the #30 sieve 16.7 %
Cumulative percent passing the #50 sieve 11.6 %
Cumulative percent passing the #100 sieve 8.2 %
Cumulative percent passing the #200 sieve 6.26 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.