Sample Record for 2020-06-05-25
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-34.7/51.6
Work Description: (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location Description: Riverside County and SBD-15-0.0/1.3
Contractor Name: Skanska-Ames, Joint Venture
Contractor Address: 1801 California Avenue, Corona, CA 92881
Resident Engineer: Roy Fisher (reports) Structure Rep.: Roy Fisher
Sample Information
DIME Sample ID: 2020-06-05-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: (951) 840-8328
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 06/05/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/05/2020
The quantity of what the sample constitutes: 1 bag combined aggregate
A brief description of the sample: AC Drum Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RJ Noble, Orange CA
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-33-0035::RJ Noble Orange
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: belt an chute
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2020-06-05-25-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 06/19/2020
Date Tested: 06/05/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Does this test use 1/4 sieve? (question for HMA Gradation Type)
|
No
|
Has the fine aggregate sample been reduced?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
Cumulative percent passing the 1/2 in. sieve
|
78 %
|
Cumulative percent passing the 3/8 in. sieve
|
63 %
|
Cumulative percent passing the #4 sieve
|
37 %
|
Cumulative percent passing the #8 sieve
|
25 %
|
Cumulative percent passing the #16 sieve
|
17 %
|
Cumulative percent passing the #30 sieve
|
10 %
|
Cumulative percent passing the #50 sieve
|
7 %
|
Cumulative percent passing the #100 sieve
|
4 %
|
Cumulative percent passing the #200 sieve
|
2.2 %
|
Test 2 of 2
DIME Test ID: 2020-06-05-25-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 06/19/2020
Date Tested: 06/05/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: