Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214589 DEA: 020J1604
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-284-0.0/8.3
Work Description: PLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location Description: PLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 24339 STATE HIGHWAY 89 N.;, BURNEY CA 96013
Resident Engineer: Structure Rep.: Unknown
DIME Sample ID: 2020-04-20-23
TL Number from the TL Form: 733182
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 04/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/21/2020
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Fine RAP, 3/8-inch
From where was the sample collected: Manufacturer
Laboratory sample identification: D78408B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ward Lake Pit
RAP Source: Ward Lake
Aggregate Size: 3/8-inch
Aggregate Source: Unknown
RAP Stockpile:
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:
DIME Test ID: 2020-04-20-23-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 06/11/2020
Date Tested: 04/23/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
1546.5 g
|
Corrected Asphalt Binder Content
|
7.67 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.00 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000 F
|
DIME Test ID: 2020-04-20-23-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 06/11/2020
Date Tested: 04/23/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
99.8 %
|
Cumulative percent passing the 3/8 in. sieve
|
98.9 %
|
Cumulative percent passing the 1/4 in. sieve
|
86.7 %
|
Cumulative percent passing the #4 sieve
|
77.5 %
|
Cumulative percent passing the #8 sieve
|
58.4 %
|
Cumulative percent passing the #16 sieve
|
43.8 %
|
Cumulative percent passing the #30 sieve
|
33 %
|
Cumulative percent passing the #50 sieve
|
23.9 %
|
Cumulative percent passing the #100 sieve
|
16.7 %
|
Cumulative percent passing the #200 sieve
|
12.3 %
|
DIME Test ID: 2020-04-20-23-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 06/11/2020
Date Tested: 04/24/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7338.0 grams
|
Mass of oven-dry sample in air for Sample 1
|
1555.0 grams
|
Mass of container filled with the sample and water for Sample 1
|
8257.0 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.445
|
Theoretical maximum density at 25°C (77°F)
|
no data
|