Unit system used?
|
US Units
|
Number of specimens
|
6
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Cross sectional area of cylinder 3
|
28.46 in^2
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Cross sectional area of cylinder 4
|
28.46 in^2
|
Cross sectional area of cylinder 5
|
28.46 in^2
|
Cross sectional area of cylinder 6
|
28.46 in^2
|
Average diameter of cylinder 1
|
6.02 in
|
Average diameter of cylinder 2
|
6.02 in
|
Compressive strength of cylinder 1
|
6689.0 psi
|
Compressive strength of cylinder 2
|
3963.5 psi
|
Average diameter of cylinder 3
|
6.02 in
|
Compressive strength of cylinder 3
|
4076.6 psi
|
Compressive strength (to nearest 10 psi)
|
4490 psi
|
Average diameter of cylinder 4
|
6.02 in
|
Compressive strength of cylinder 4
|
4008.4 psi
|
Average diameter of cylinder 5
|
6.02 in
|
Compressive strength of cylinder 5
|
3956.8 psi
|
Average diameter of cylinder 6
|
6.02 in
|
Compressive strength of cylinder 6
|
4220 psi
|
Maximum load on cylinder 1
|
190370 lb
|
Maximum load on cylinder 2
|
112800 lb
|
Maximum load on cylinder 3
|
116020 lb
|
Maximum load on cylinder 4
|
114080 lb
|
Maximum load on cylinder 5
|
112610 lb
|
Maximum load on cylinder 6
|
120100 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
4
|
Type of fracture pattern of cylinder 4
|
2
|
Type of fracture pattern of cylinder 5
|
1
|
Type of fracture pattern of cylinder 6
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Correction factor for cylinder 6
|
1
|
Age of specimen
|
1 days
|