Print Report | Back to Sample Detail

Sample Record for 2020-06-04-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214029 DEA: 07301104 EFIS: 0714000009 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60,710-710-R2.8/11.8, 24.1/25.1
Work Description: Roadway ex, place jointed plain concrete pavement & concrete barrieres
Location Description: In Los Angeles County at avocado Heights on Route 60 from 0.5 Mile west of Route 60/710 Separation to Route 60/605 Separation AND on Route 710 from 0.5 miles south of Route 710/60 Separation to 0.5 mile north of Route 710/60 Separation.
Contractor Name: GUY F. ATKINSON CONSTRUCTION, LLC
Contractor Address: 18201 Von Karman Ave #800, Irvine, CA 92612
Resident Engineer: Sepand Minovi Structure Rep.: Rick Jensen

Sample Information

DIME Sample ID: 2020-06-04-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 06/04/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/05/2020
The quantity of what the sample constitutes: JMF 4 Bags
A brief description of the sample: 1/2 RHMA-G-SP Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: 0309G-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt-Irwindale

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample: 1/2 RHMA-G-SP
The fabricator/manufacturer designation for the sample: Unknown
The plant number: 106836
A detailed description of where the material sample was collected: Belt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:

Test Results

Test 1 of 11

DIME Test ID: 2020-06-04-3-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 06/24/2020
Date Tested: 06/12/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: Combined Virgin aggregate
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 96 %
Cumulative percent passing the 3/8 in. sieve 82 %
Cumulative percent passing the #4 sieve 37 %
Cumulative percent passing the #8 sieve 23 %
Cumulative percent passing the #16 sieve 14 %
Cumulative percent passing the #30 sieve 9 %
Cumulative percent passing the #50 sieve 6 %
Cumulative percent passing the #100 sieve 4 %
Cumulative percent passing the #200 sieve 2.9 %

Test 2 of 11

DIME Test ID: 2020-06-04-3-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 06/24/2020
Date Tested: 06/16/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 100 %
Weighted average percentage of fractured, coarse, 1 faced particles 100 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 3 of 11

DIME Test ID: 2020-06-04-3-3
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 07/07/2020.
Reason: retested

Test 4 of 11

DIME Test ID: 2020-06-04-3-4
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 07/07/2020.
Reason: retested

Test 5 of 11

DIME Test ID: 2020-06-04-3-5
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 06/24/2020
Date Tested: 06/15/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation C
Mass of sample on No.12 sieve (after 500 revolutions) 3863 grams
Percent loss after 100 revolutions 6 %
Percent loss after 500 revolutions 23 %

Test 6 of 11

DIME Test ID: 2020-06-04-3-6
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 06/24/2020
Date Tested: 06/15/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 72

Test 7 of 11

DIME Test ID: 2020-06-04-3-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 06/24/2020
Date Tested: 06/16/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method B
Determination By Mass
Dimensional ratio used 5:1
Weighted percentage of particles (by mass) that were flat and elongated 2 %
Weighted percentage of particles (by mass) that were not flat and elongated 98 %

Test 8 of 11

DIME Test ID: 2020-06-04-3-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 07/07/2020.
Reason: retested

Test 9 of 11

DIME Test ID: 2020-06-04-3-9
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 07/07/2020
Date Tested: 07/03/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk SSD
Specific Gravity 2.756
Absorption 0.6 %

Test 10 of 11

DIME Test ID: 2020-06-04-3-10
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 07/07/2020
Date Tested: 07/03/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.676
Bulk specific gravity (SSD Basis) 2.719
Apparent specific gravity 2.796
Absorption 1.6 %

Test 11 of 11

DIME Test ID: 2020-06-04-3-11
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 07/07/2020
Date Tested: 06/16/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.676
Average uncompacted voids 47.1 %