*Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Sample Record for 2020-06-05-12


Project Information

Project ID: 88888 DEA: STOCK EFIS: STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Contractor Address:
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-06-05-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 06/05/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2020
The quantity of what the sample constitutes: 3
A brief description of the sample: Ductile Iron Casting
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:

Material Information

Heat Number (s): C100 E050 E060
Part Number (s): 27 6 AH 19 6 PC1 BP
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: SDI

Test Results

Test 1 of 1

DIME Test ID: 2020-06-05-12-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 06/10/2020
Date Tested: 06/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 3
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
C1000.50.196356340911121610.8fsaylor
E0500.50.19635627211098449.4fsaylor
E0600.50.19635640091101608.2fsaylor
UTM 67kip
Temperature 72 F