Sample Record for 2020-06-07-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 208973 DEA: 120H1004 EFIS: 1200000180 COOP: 120670
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405,73,405,605-9.3/24.3
Work Description: (Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location Description: Orange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
Contractor Name: OC 405 Partners
Contractor Address: 3100 W Lake Center Dr, Santa Ana, CA 92704
Resident Engineer: Hank Alonso (reports) Structure Rep.: Alex Angha (reports)
Sample Information
DIME Sample ID: 2020-06-07-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Department Acceptance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 06/07/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/10/2020
The quantity of what the sample constitutes: 25
A brief description of the sample: #8 epoxy coated grade 75 rebar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Eng
Material Information
Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: #8
Nut Specification for Threaded Bar: ASTM A108
System Manufacturer: Williams Form Eng
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): D19104229
Nut Heat Number(s): 8296508
Bar Lot Number: DL1910422903
Nut Lot Number: 8S5D
Coupler Heat Number(s):
Coupler Grade:
Test Results
Test 1 of 4
DIME Test ID: 2020-06-07-1-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 06/10/2020
Date Tested: 06/10/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Stripped But Made Strengh
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | | No.8/25mm | | 0.79 | 117291 | 103164 | -100 | Nut Stripped But Made Strengh | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 2 of 4
DIME Test ID: 2020-06-07-1-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 06/10/2020
Date Tested: 06/10/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | | No.8/25mm | | 0.79 | 128129 | 118583 | 6.35 | A615 Threaded Bar and Nut | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 3 of 4
DIME Test ID: 2020-06-07-1-3
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 06/10/2020
Date Tested: 06/10/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | | No.8/25mm | | 0.79 | 127939 | 104539 | 5.82 | A615 Threaded Bar and Nut | bewing |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 4 of 4
DIME Test ID: 2020-06-07-1-4
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 06/10/2020
Date Tested: 06/10/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
10 mils
|
Upper spec. limit USL
|
15 mils
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
First Bar Mean
|
9.93
|
Second Bar Mean
|
9.69
|
Total mean value
|
9.81
|