Print Report | Back to Sample Detail

Sample Record for 2020-05-14-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214756 DEA: 050N7AU4 EFIS: 0520000030 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-1.4/4.8
Work Description: Segment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location Description: CARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Rd, Santa Barbara, CA 93160
Resident Engineer: Taylor Merlo Structure Rep.: Bernardo Hernandez

Sample Information

DIME Sample ID: 2020-05-14-38
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/15/2020
The quantity of what the sample constitutes: 162 tons temp area
A brief description of the sample: 6 boxes HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification: D5 20-A-033
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Santa Paula

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 9
HMA Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2020-05-14-38-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/28/2020
Date Tested: 05/27/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test: 4.35% to 5.15%.
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2046.1 g
Corrected Asphalt Binder Content 4.35 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.33 %
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature 1000 F

Test 2 of 4

DIME Test ID: 2020-05-14-38-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/28/2020
Date Tested: 05/18/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.520
Theoretical maximum density at 25°C (77°F) no data

Test 3 of 4

DIME Test ID: 2020-05-14-38-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/28/2020
Date Tested: 05/28/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.439
Bulk Specific Gravity 2 2.448
Bulk Specific Gravity 3 2.449
Average Bulk Specific Gravity 2.445

Test 4 of 4

DIME Test ID: 2020-05-14-38-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/28/2020
Date Tested: 05/28/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test: 2.5 to 5.5
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.2 %
Percent Air Voids 2 2.9 %
Percent Air Voids 3 2.8 %
Percent Air Voids Average 3.0 %