Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214756 DEA: 050N7AU4 EFIS: 0520000030
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-1.4/4.8
Work Description: Segment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location Description: CARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Rd, Santa Barbara, CA 93160
Resident Engineer: Taylor Merlo Structure Rep.: Bernardo Hernandez
DIME Sample ID: 2020-05-14-38
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/15/2020
The quantity of what the sample constitutes: 162 tons temp area
A brief description of the sample: 6 boxes HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification: D5 20-A-033
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Santa Paula
DIME Test ID: 2020-05-14-38-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/28/2020
Date Tested: 05/27/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test: 4.35% to 5.15%.
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2046.1 g
|
Corrected Asphalt Binder Content
|
4.35 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.33 %
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000 F
|
DIME Test ID: 2020-05-14-38-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/28/2020
Date Tested: 05/18/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.520
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2020-05-14-38-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/28/2020
Date Tested: 05/28/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.439
|
Bulk Specific Gravity 2
|
2.448
|
Bulk Specific Gravity 3
|
2.449
|
Average Bulk Specific Gravity
|
2.445
|
DIME Test ID: 2020-05-14-38-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/28/2020
Date Tested: 05/28/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test: 2.5 to 5.5
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
3.2 %
|
Percent Air Voids 2
|
2.9 %
|
Percent Air Voids 3
|
2.8 %
|
Percent Air Voids Average
|
3.0 %
|