Sample Record for 2020-05-20-9


Project Information

Project ID: 3825 DEA: 07138204 EFIS: 0700000142 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47,103-3.5/4.6,0.0/1.1
Work Description: REPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location Description: LOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
Contractor Name: M C M CONSTRUCTION INC Contractor Address: P O BOX 620
Resident Engineer: Daniel Leon Structure Rep.: Chen, Andy

Sample Information

DIME Sample ID: 2020-05-20-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 05/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/26/2020
The quantity of what the sample constitutes: 4
A brief description of the sample: Coupon Casting
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:

Material Information

Heat Number (s): D080, B250, C110, C040
Part Number (s): 68 04 2532 68 31 172 68 07 1532 68 05 144
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: DSI

Test Results

Test 1 of 1

DIME Test ID: 2020-05-20-9-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/29/2020
Date Tested: 05/28/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Number of Samples 8
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
D0800.5020.19792643551134457.3fsaylor
D0800.5020.19792637851112427.3fsaylor
B2500.5020.19792641801111367.2fsaylor
B2500.5020.19792640431113327.2fsaylor
C1100.5020.19792642991142047.8fsaylor
C1100.5020.19792642681142687.9fsaylor
C0400.5020.19792617911031517.1fsaylor
C0400.5020.19792614411035197fsaylor
UTM 67kip
Temperature 72 F