Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-05-05-24
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 05/05/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/05/2020
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Type III Cement
From where was the sample collected: Source
Laboratory sample identification: CM205024
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LaFarge Holcim
DIME Test ID: 2020-05-05-24-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 09/03/2020
Date Tested: 06/09/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 1 day test
-- Specimen 1 break was outside allowable range per Section 13 of ASTM C109-16. Average compressive strength shown is based on remaining 2 specimens.
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
1 days
|
The amount of flow
|
no data %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
3342 psi
|
Compressive strength of 2nd specimen
|
2877 psi
|
Compressive strength of 3rd specimen
|
3041 psi
|
Average Compressive strength (to nearest 10 psi)
|
2960 psi
|
DIME Test ID: 2020-05-05-24-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 09/03/2020
Date Tested: 06/11/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
3 days
|
The amount of flow
|
no data %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
4495 psi
|
Compressive strength of 2nd specimen
|
4808 psi
|
Compressive strength of 3rd specimen
|
4696 psi
|
Average Compressive strength (to nearest 10 psi)
|
4670 psi
|
DIME Test ID: 2020-05-05-24-4
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 09/03/2020
Date Tested: 06/23/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type IV grade reagent water
|
Initial time of setting
|
82 min
|
Final time of setting
|
no data
|
DIME Test ID: 2020-05-05-24-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 09/03/2020
Date Tested: 08/13/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.15
|
Water Content
|
248
|
The amount of flow (In percent)
|
86 %
|
The amount of water used (In percent)
|
70.86 %
|
Net Weight of Sample
|
842.8 grams
|
Air Content
|
6 %
|