*Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Sample Record for 2020-05-21-6


Project Information

Project ID: 213569 DEA: 024F2104 EFIS: 0212000072 QA Service Level: 1
DIST-CO-RTE-PM: 02-MOD-299-25.6 to 1.5
Work Description:
Location Description:
Contractor Name: WEST COAST CONTRACTORS, INC. Contractor Address: 61050 Highway 101
Resident Engineer: Mike Zdenek Structure Rep.: Duran, Ryan G

Sample Information

DIME Sample ID: 2020-05-21-6
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 05/21/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/22/2020
The quantity of what the sample constitutes: 27
A brief description of the sample: #10 Button Heads
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 4090228
Head Manufacturer Lot Number(s): A182386
Rebar Size: #10
Headed Bar Model Name: BNX
Size of Head: Full Size - 9x
Head Connection Type: Crimped Head
Head Shape: Circular
Rebar Manufacturer: CMC
Head Manufacturer: Barsplice
Head Fabricator: Barsplice BNX Buttonheads
Material Standard Code: ASTM A706

Test Results

Test 1 of 3

DIME Test ID: 2020-05-21-6-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/22/2020
Date Tested: 05/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments: Ok Necking
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
21.2712262396553Ok Neckingbewing
Temperature 72 f
UTM 400kip

Test Results

Test 2 of 3

DIME Test ID: 2020-05-21-6-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/22/2020
Date Tested: 05/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments: Ok Necking
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
21.2712289696768Ok Neckingbewing
Temperature 72 f
UTM 400kip

Test Results

Test 3 of 3

DIME Test ID: 2020-05-21-6-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 05/22/2020
Date Tested: 05/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments: Ok Necking
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
21.2712246596429Ok Neckingbewing
Temperature 72 f
UTM 400kip