Sample Record for 2020-05-13-12
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214227 DEA: 100Q1214 EFIS: 1014000167
QA Service Level: 1
DIST-CO-RTE-PM: 10-MER-99-28.2/R37.3
Work Description: PLACE REINFORCED CONCRETE PAVEMENT, HMA & FIBER OPTIC CABLE SYSTEM.
Location Description: MERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Nathaniel Tumminello Structure Rep.: Karen Sampson
Sample Information
DIME Sample ID: 2020-05-13-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 05/13/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/18/2020
The quantity of what the sample constitutes: 10
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 18644-1
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 3.5" x 20" x 28"
Comments: Unknown
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA
Test Results
Test 1 of 4
DIME Test ID: 2020-05-13-12-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/20/2020
Date Tested: 05/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
53
|
Reading #2
|
52
|
Reading #3
|
52
|
Reading #4
|
53
|
Reading #5
|
52
|
Mean
|
52.4
|
Test 2 of 4
DIME Test ID: 2020-05-13-12-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/20/2020
Date Tested: 05/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
5
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.094
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2708.82 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.094
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2563.02 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.096
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2056.41 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Sample 4 Median Thickness
|
0.093
|
Sample 4 Thickness all Within 0.003 inch?
|
Yes
|
Sample 4 Ultimate Tensile
|
2484.61 lbf/in^2
|
Sample 4 Elongation (350% Min)
|
Pass
|
Sample 5 Median Thickness
|
0.095
|
Sample 5 Thickness all Within 0.003 inch?
|
Yes
|
Sample 5 Ultimate Tensile
|
2446.35 lbf/in^2
|
Sample 5 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2484.6 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2020-05-13-12-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/20/2020
Date Tested: 05/19/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.097
|
Sample 1 Tear Strength
|
225.8
|
Sample 2 Median Thickness
|
0.09
|
Sample 2 Tear Strength
|
199.8
|
Sample 3 Median Thickness
|
0.097
|
Sample 3 Tear Strength
|
237.9
|
Median of the Tear Strength Values
|
225.8 lb/in
|
Test 4 of 4
DIME Test ID: 2020-05-13-12-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/20/2020
Date Tested: 05/20/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: