Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214520 DEA: 051H9804 EFIS: 0517000043
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-78.4/79.0
Work Description: ROADWAY EXCAVATION, PLACE AGGREGATE BASE, HMA AND RHMA-G.
Location Description: SANTA BARBARA COUNTY NEAR SANTA MARIA FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF SOLOMON SUMMIT UNDERCROSSING
Contractor Name: Calportland Construction
Contractor Address: 1625 E DONOVAN RD, SANTA MARIA
Resident Engineer: Lilian (Poh Chu) Bennetzen Structure Rep.: Unknown
DIME Sample ID: 2020-05-06-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/06/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/13/2020
The quantity of what the sample constitutes: One JMF Verification
A brief description of the sample: Boxes of RHMA-G
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CalPortland Garey
DIME Test ID: 2020-05-06-16-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/19/2020
Date Tested: 05/15/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2318.5 g
|
Corrected Asphalt Binder Content
|
7.92 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.78 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
538 F
|
DIME Test ID: 2020-05-06-16-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 05/19/2020
Date Tested: 05/15/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.205
|
Bulk Specific Gravity 2
|
2.208
|
Bulk Specific Gravity 3
|
2.202
|
Average Bulk Specific Gravity
|
2.205
|
DIME Test ID: 2020-05-06-16-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/19/2020
Date Tested: 05/15/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.306
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2020-05-06-16-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 05/19/2020
Date Tested: 05/15/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
4.4 %
|
Percent Air Voids 2
|
4.2 %
|
Percent Air Voids 3
|
4.5 %
|
Percent Air Voids Average
|
4.4 %
|
DIME Test ID: 2020-05-06-16-5
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 05/19/2020
Date Tested: 05/18/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test: CPD 19-8 CCO looks at average rut depth at 15000 passes for PG 64-16, and inflection point is report only.
Test Result Compliance: complies
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
15000
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
15000
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
3.05 mm
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
3.05 mm
|
Stripping Inflection Point (Wheel A)
|
>16600
|
Stripping Inflection Point (Wheel B)
|
>16600
|