Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-05-14-26
TL Number from the TL Form:
Sample Submitted By Organization: Vulcan Materials Company - Pleasanton
Sample Organization Contact: (925) 260-3017
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 05/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: Manufactured Sand Cold feed Aggregate
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Materials
Source Identification (SMARA, name of Pit or Job Site): 91-01-0010::CALMAT/PLEASANTON
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Stockpile
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: fine
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:
DIME Test ID: 2020-05-14-26-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 05/18/2020
Date Tested: 05/14/2020
Submitted By Organization: Vulcan Materials Company - Pleasanton
Organization Address: 52 El Charro Road,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: ruedid@vmcmail.com
Organization Phone: (925) 260-3017
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
Cumulative percent passing the #4 sieve
|
99 %
|
Cumulative percent passing the #8 sieve
|
73 %
|
Cumulative percent passing the #16 sieve
|
43 %
|
Cumulative percent passing the #30 sieve
|
28 %
|
Cumulative percent passing the #50 sieve
|
18 %
|
Cumulative percent passing the #100 sieve
|
9 %
|
Cumulative percent passing the #200 sieve
|
4.5 %
|