Project ID: 213958 DEA: 010F9604 EFIS: 0116000109
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-124.5
Work Description: LITTLE LOST MAN FISH PASSAGE
Location Description: HUMBOLDT COUNTY NEAR ORICK 0.2 MILE SOUTH OF LOST MAN CREEK BRIDGE
Contractor Name: MCCULLOUGH CONSTRUCTION INC
Contractor Address: 57 Aldergrove Rd., Arcata, CA 95521
Resident Engineer: Karen Sanders Structure Rep.: Brian Cinkutis
DIME Sample ID: 2020-05-08-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 05/08/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/13/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dynamic Rubber
Mfg. Lot Number(s): CR55-007-20
Material/Compound/Elastomer ID: na
Samples Representing: 31
Description (size): 2.88"x14"x14"
Comments: Unknown
Description (Number of Shims): 5
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Dynamic Rubber
Batch Number: na
DIME Test ID: 2020-05-08-12-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/14/2020
Date Tested: 05/14/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
52
|
Reading #2
|
54
|
Reading #3
|
52
|
Reading #4
|
52
|
Reading #5
|
50
|
Mean
|
52
|
DIME Test ID: 2020-05-08-12-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/14/2020
Date Tested: 05/14/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.078
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2939.53 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.08
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2938.14 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.082
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2890.94 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2938.1 lbf/in^2
|
DIME Test ID: 2020-05-08-12-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/14/2020
Date Tested: 05/14/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.078
|
Sample 1 Tear Strength
|
233.5
|
Sample 2 Median Thickness
|
0.079
|
Sample 2 Tear Strength
|
231.7
|
Sample 3 Median Thickness
|
0.083
|
Sample 3 Tear Strength
|
222.6
|
Median of the Tear Strength Values
|
231.7 lb/in
|
DIME Test ID: 2020-05-08-12-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/14/2020
Date Tested: 05/14/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: