Sample Record for 2020-03-27-16
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214190 DEA: 024G41U4 EFIS: 0218000047
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS,SIS-5-Var
Work Description: REPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location Description: SHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
Contractor Name: J.F. Shea Construction, Inc.
Contractor Address: 17400 Clear Creek Road, Redding, CA 96001
Resident Engineer: Nicole Mallory Structure Rep.: Adam Scardaci
Sample Information
DIME Sample ID: 2020-03-27-16
TL Number from the TL Form: 036602
Sample Submitted By Organization: CT D02 - North Region Materials Lab
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 03/27/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2020
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4-inch Type Aggregate (Treated Virgin)
From where was the sample collected: Manufacturer
Laboratory sample identification: D78374A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fawndale Rock and Asphalt - Redding, CA
Material Information
Source Identification (SMARA or name of Pit): 91-45-0017::FAWNDALE ROCK QUARRY
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Cold Feed
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: JMF 18-03-XXXm
Lot number: Unknown
Sublot number: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2020-03-27-16-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 05/11/2020
Date Tested: 04/07/2020
Submitted By Organization: CT D02 - North Region Materials Lab
Organization Address: 1657 Riverside Drive, MS-83,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Does this test use 1/4 sieve? (question for HMA Gradation Type)
|
Yes
|
Total mass of material in the sample
|
7910.7 grams
|
Cumulative mass retained on the 1 1/2 in. sieve
|
0 grams
|
Cumulative mass retained on the 1 in. sieve
|
0 grams
|
Cumulative mass retained on the 3/4 in. sieve
|
130 grams
|
Cumulative mass retained on the 1/2 in. sieve
|
1624 grams
|
Cumulative mass retained on the 3/8 in. sieve
|
2668 grams
|
Mass retained on the 1/4 in. sieve
|
3846 grams
|
Cumulative mass retained on the #4 sieve
|
4329 grams
|
Total sample mass passing the #4 sieve
|
3581.7 grams
|
Total mass of fine material in the sample
|
517.6 grams
|
Cumulative mass retained on the #8 sieve
|
178.3 grams
|
Cumulative mass retained on the #16 sieve
|
309.4 grams
|
Cumulative mass retained on the #30 sieve
|
379.3 grams
|
Cumulative mass retained on the #50 sieve
|
415.9 grams
|
Cumulative mass retained on the #100 sieve
|
438.9 grams
|
Cumulative mass retained on the #200 sieve
|
454.7 grams
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
98.4 %
|
Cumulative percent passing the 1/2 in. sieve
|
79.5 %
|
Cumulative percent passing the 3/8 in. sieve
|
66.3 %
|
Cumulative percent passing the 1/4 in. sieve
|
51.4 %
|
Cumulative percent passing the #4 sieve
|
45.3 %
|
Cumulative percent passing the #8 sieve
|
29.7 %
|
Cumulative percent passing the #16 sieve
|
18.2 %
|
Cumulative percent passing the #30 sieve
|
12.1 %
|
Cumulative percent passing the #50 sieve
|
8.9 %
|
Cumulative percent passing the #100 sieve
|
6.9 %
|
Cumulative percent passing the #200 sieve
|
5.5 %
|
Tests Assigned to this Sample
DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
No tests have been assigned to this sample. |