Print Report | Back to Sample Detail

Sample Record for 2020-05-04-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-05-04-10
TL Number from the TL Form:
Sample Submitted By Organization: Teichert Materials - Sacramento
Sample Organization Contact: (916) 386-6974
Type of Sample: Quality Control
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 05/04/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/04/2020
The quantity of what the sample constitutes: JMF Prequalification Program
A brief description of the sample: 1/2" Recycled Asphalt Pavement
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Materials Vernalis

Material Information

RAP Source: Teichert Materials Vernalis
Aggregate Size: Unknown
Aggregate Source: Unknown
RAP Stockpile: Static
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2020-05-04-10-1
Test Method: AASHTO T164-14: Standard Method of Test for Quantitative Extraction of Asphalt Binder from Hot Mix Asphalt (HMA) (Asphalt Binder Content)
Verified Date: 05/05/2020
Date Tested: 05/05/2020
Submitted By Organization: Teichert Materials - Sacramento
Organization Address: 3500 American River Drive,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95864
Organization Email: egifford@teichert.com
Organization Phone: (916) 386-6974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected Asphalt Binder Content 4.86 %

Test 2 of 3

DIME Test ID: 2020-05-04-10-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 05/05/2020
Date Tested: 05/05/2020
Submitted By Organization: Teichert Materials - Sacramento
Organization Address: 3500 American River Drive,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95864
Organization Email: egifford@teichert.com
Organization Phone: (916) 386-6974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 96 %
Cumulative percent passing the 3/8 in. sieve 90 %
Cumulative percent passing the 1/4 in. sieve 0 %
Cumulative percent passing the #4 sieve 67 %
Cumulative percent passing the #8 sieve 51 %
Cumulative percent passing the #16 sieve 36 %
Cumulative percent passing the #30 sieve 27 %
Cumulative percent passing the #50 sieve 19 %
Cumulative percent passing the #100 sieve 13 %
Cumulative percent passing the #200 sieve 8.6 %

Test 3 of 3

DIME Test ID: 2020-05-04-10-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/05/2020
Date Tested: 05/05/2020
Submitted By Organization: Teichert Materials - Sacramento
Organization Address: 3500 American River Drive,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95864
Organization Email: egifford@teichert.com
Organization Phone: (916) 386-6974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.445
Theoretical maximum density at 25°C (77°F) no data