Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213229 DEA: 050A0504 EFIS: 0500000007
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-1-15.6
Work Description: BRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE.
Location Description: SANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE
Contractor Name: Cal Portland Construction
Contractor Address: 1625 E DONOVAN RD, SANTA MARIA, CA 93454
Resident Engineer: Lilian Bennetzen Structure Rep.: Bernardo Hernandez
DIME Sample ID: 2020-05-01-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 05/01/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/11/2020
The quantity of what the sample constitutes: (1 pack) .6"Ø 8,714 ft. Long
A brief description of the sample: (1) .6"Ø 4 ft. Long
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: OLDCAST PRECAST PERRIS
Comments:
Reel/Coil/Pack Number(s): S379038-2
Number of Coils: 1
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0541520
Mfg. Lot Number(s): S379038-2
Manufacturer(s): Sumiden Wire
DIME Test ID: 2020-05-01-6-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/06/2020
Date Tested: 05/05/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0541520 | S379038-2 | 0.214 | 60067 | 55965.8 | 28.7 | 1.92 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|
DIME Test ID: 2020-05-01-6-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/06/2020
Date Tested: 05/05/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0541520 | S379038-2 | 0.214 | 59878 | 55778.1 | 28.5 | 1.73 | bewing |
| |
UTM
|
120kip
|
Temperature
|
72 f
|
Extensometers
|
no data
|