*Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Sample Record for 2020-04-29-9


Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Contractor Address:
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-04-29-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/29/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/29/2020
The quantity of what the sample constitutes: 16 boxes 1/2 HMA
A brief description of the sample: JMF
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: Unknown
Sublot number: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2020-04-29-9-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Asphalt Binder Content)
Verified Date: 04/29/2020
Date Tested: 04/29/2020
Submitted By Organization: CT HQ - Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Blvd
Test General Comments:
Additional Comments When Verified:
Test procedure used? Method A
Asphalt Binder Content 5.23 %
Mass of HMA prior to ignition no data
Mass of aggregate remaining after ignition no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Test Temperature no data