Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 031E0604 Cty YUB Rte 70 PM 15.5/16.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Manoharan Selvendran |
Date Reported: |
06/03/2020 |
|
Address: |
TL Number: |
79-A1 |
||
City: |
||||
Project Name: SIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055. |
||||
Prime Contractor: MCM Construction |
||||
Sample Taken Date: |
04/21/2020 |
Mix Design: |
1519161 |
|
Contractor: Unknown |
Location: NEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019. |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.37 | 6.01 | 6020.0 | 170783 | 1 |
2 | 28.56 | 6.03 | 6178.0 | 176426 | 1 |
DIME Test ID: 2020-04-21-11-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6100
Age of specimen: 43 days
Certified By: Phillip Montes
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing