Print Report | Back to Sample Detail

Sample Record for 2020-03-12-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 44444 DEA: ASCP EFIS: ASCP QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-12-15
TL Number from the TL Form: 031220-035
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 03/12/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/08/2020
The quantity of what the sample constitutes: 4 Cans
A brief description of the sample: Asphalt Binder Sample
From where was the sample collected: Manufacturer
Laboratory sample identification: AB205074
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: World Oil

Material Information

Performance Grade: PG58-22
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier:
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2020-03-12-15-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 04/22/2020
Date Tested: 04/22/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers? One
Any material loss from containers during heating process/testing? No
Mass of empty container #1 171.197 grams
Mass of container #1 before test (m1i) 206.633 grams
Mass of container #1 after test (m1f) 206.634 grams
Average mass change 0.003 percent