Print Report | Back to Sample Detail

Sample Record for 2020-03-20-20

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R3.8/R11.7
Work Description: WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB
Location Description: SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING
Contractor Name: J.F. SHEA CONSTRUCTION
Contractor Address: P.O. BOX 494519, REDDING, CA 96049-4519
Resident Engineer: Henry Benner Structure Rep.: Eric Chaffee

Sample Information

DIME Sample ID: 2020-03-20-20
TL Number from the TL Form: 897551
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Department Acceptance
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 03/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 03/23/2020
The quantity of what the sample constitutes: 50000 ton
A brief description of the sample: RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D78363B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fawndale Rock and Asphalt - Redding, CA

Material Information

RAP Source: Fawndale Rock and Asphalt, Redding, CA
Aggregate Size: 3/8-inch
Aggregate Source: Unknown
RAP Stockpile:
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2020-03-20-20-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/14/2020
Date Tested: 03/25/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1373.2 g
Corrected Asphalt Binder Content 6.2 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor no data
Test Temperature 1000 F

Test 2 of 3

DIME Test ID: 2020-03-20-20-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 04/14/2020
Date Tested: 03/26/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 98.9 %
Cumulative percent passing the 1/4 in. sieve 82.9 %
Cumulative percent passing the #4 sieve 67.3 %
Cumulative percent passing the #8 sieve 44.8 %
Cumulative percent passing the #16 sieve 31.9 %
Cumulative percent passing the #30 sieve 23.4 %
Cumulative percent passing the #50 sieve 17.3 %
Cumulative percent passing the #100 sieve 13.1 %
Cumulative percent passing the #200 sieve 10.3 %

Test 3 of 3

DIME Test ID: 2020-03-20-20-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/14/2020
Date Tested: 03/26/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed no data
Mass of container filled with water 7338 grams
Mass of oven-dry sample in air for Sample 1 1733 grams
Mass of container filled with the sample and water for Sample 1 8390 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.544
Theoretical maximum density at 25°C (77°F) no data