Sample Record for 2020-04-10-7
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.: Sami Deeb
Sample Information
DIME Sample ID: 2020-04-10-7
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Independent Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/10/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/10/2020
The quantity of what the sample constitutes: 4 Anchor Bolt Assemblies
A brief description of the sample: ASTM F1554 Gr 55 Anchor Bolt with nut and washer
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: GDB
The fabricator/manufacturer/facility name: Universal Industrial Sales
Material Information
Rocap Number(s):
Heat Number(s): PL17100835, 188194, B916323
Nut Mfg. Lot Number(s): DDYO
Washer Mfg. Lot Number(s): D7581
Bolt Specification: ASTM F1554 GR 55
Bolt Length(s): 2'-2"
Nut Specification: ASTM A153/F2329 per ASTM A563 Grade DH, ASTM A194 Grade 2H
Washer Specification: ASTM F436, ASTM F844
Finish: hot dip galvanizing HDG
Diameter/Size: 2"
Bolt Mfg. Lot Number: PL1710083501
Rocap Test Requirement(s):
Lubricant Requirements(s):
Test Results
Test 1 of 29
DIME Test ID: 2020-04-10-7-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | PL17100835 | 0.503 | 0.199 | 64702 | 90276 | 27.2 | fsaylor |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
Test 2 of 29
DIME Test ID: 2020-04-10-7-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | PL17100835 | 0.5 | 0.196 | 65438 | 90221 | 27.2 | fsaylor |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
Test 3 of 29
DIME Test ID: 2020-04-10-7-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17100835
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
2 in
|
Bolt Length
|
26 in
|
Gage Type
|
Pass
|
Test 4 of 29
DIME Test ID: 2020-04-10-7-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17100835
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
2 in
|
Bolt Length
|
26 in
|
Gage Type
|
Pass
|
Test 5 of 29
DIME Test ID: 2020-04-10-7-5
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17100835
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
2 in
|
Bolt Length
|
26 in
|
Gage Type
|
Pass
|
Test 6 of 29
DIME Test ID: 2020-04-10-7-6
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Gage Type
|
Pass
|
Test 7 of 29
DIME Test ID: 2020-04-10-7-7
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Gage Type
|
Pass
|
Test 8 of 29
DIME Test ID: 2020-04-10-7-8
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Gage Type
|
Pass
|
Test 9 of 29
DIME Test ID: 2020-04-10-7-9
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Gage Type
|
Pass
|
Test 10 of 29
DIME Test ID: 2020-04-10-7-10
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Gage Type
|
Pass
|
Test 11 of 29
DIME Test ID: 2020-04-10-7-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17100835
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
2 in
|
Bolt Length
|
26 in
|
Measurement Average
|
6.68 mils
|
Test 12 of 29
DIME Test ID: 2020-04-10-7-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17100835
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
2 in
|
Bolt Length
|
26 in
|
Measurement Average
|
5.61 mils
|
Test 13 of 29
DIME Test ID: 2020-04-10-7-13
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
PL17100835
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
YELLOW PAINT
|
Size
|
2 in
|
Bolt Length
|
26 in
|
Measurement Average
|
5.78 mils
|
Test 14 of 29
DIME Test ID: 2020-04-10-7-14
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.41 mils
|
Test 15 of 29
DIME Test ID: 2020-04-10-7-15
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.67 mils
|
Test 16 of 29
DIME Test ID: 2020-04-10-7-16
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.46 mils
|
Test 17 of 29
DIME Test ID: 2020-04-10-7-17
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
7.36 mils
|
Test 18 of 29
DIME Test ID: 2020-04-10-7-18
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
6.03 mils
|
Test 19 of 29
DIME Test ID: 2020-04-10-7-19
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.44 mils
|
Test 20 of 29
DIME Test ID: 2020-04-10-7-20
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.46 mils
|
Test 21 of 29
DIME Test ID: 2020-04-10-7-21
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.05 mils
|
Test 22 of 29
DIME Test ID: 2020-04-10-7-22
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.78 mils
|
Test 23 of 29
DIME Test ID: 2020-04-10-7-23
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.27 mils
|
Test 24 of 29
DIME Test ID: 2020-04-10-7-24
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
25.07
|
Spacing
|
Ok
|
Test 25 of 29
DIME Test ID: 2020-04-10-7-25
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
27.62
|
Spacing
|
Ok
|
Test 26 of 29
DIME Test ID: 2020-04-10-7-26
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
DDYO
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
2H DH D/N
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
27.7
|
Spacing
|
Ok
|
Test 27 of 29
DIME Test ID: 2020-04-10-7-27
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.1
|
Spacing
|
Ok
|
Test 28 of 29
DIME Test ID: 2020-04-10-7-28
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
40
|
Spacing
|
Ok
|
Test 29 of 29
DIME Test ID: 2020-04-10-7-29
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/08/2020
Date Tested: 05/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.65
|
Spacing
|