Print Report | Back to Sample Detail

Sample Record for 2020-03-24-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214421 DEA: 01362704 EFIS: 0116000031 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-1-62.2/R78.9
Work Description: HOT MIX ASPHALT OVERLAY.
Location Description: MENDOCINO COUNTY NEAR FORT BRAGG FROM 0.1 MILE NORTH OF PUDDING CREEK BRIDGE TO 0.6 MILE NORTH OF WAGES CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 1324 South State Street, Ukiah, CA 95482
Resident Engineer: Roozbeh Hadipour Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-24-4
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/24/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/10/2020
The quantity of what the sample constitutes: 200
A brief description of the sample: ASTM A193 HDG Anchor Rod
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BMSI

Material Information

Rocap Number(s): N/A
Heat Number(s): 10610630
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A193 B7
Bolt Length(s): 12"
Nut Specification: N/A
Washer Specification: N/A
Finish: ASTM A153
Diameter/Size: 5/8" DIAMETER
Bolt Mfg. Lot Number: N/A
Rocap Test Requirement(s): no
Lubricant Requirements(s):

Test Results

Test 1 of 18

DIME Test ID: 2020-03-24-4-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1AUNC 5/8 0.2263139113913888512861929068A193 Rod
UTM 400kip
Temperature 72

Test 2 of 18

DIME Test ID: 2020-03-24-4-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1BUNC 5/8 0.2263138713913886512803128935A193 Rod
UTM 400kip
Temperature 72

Test 3 of 18

DIME Test ID: 2020-03-24-4-3
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1CUNC 5/8 0.2263128813913840512926229213A193 Rod
UTM 400kip
Temperature 72

Test 4 of 18

DIME Test ID: 2020-03-24-4-4
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1DUNC 5/8 0.2263104513813731611986827090A193 Rod
UTM 400kip
Temperature 72

Test 5 of 18

DIME Test ID: 2020-03-24-4-5
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
5EUNC 5/8 0.2263167414014014613063529523A193 Rod
UTM 400kip
Temperature 72

Test 6 of 18

DIME Test ID: 2020-03-24-4-6
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1FUNC 5/8 0.2263116013813780612772928867A193 Rod
UTM 400kip
Temperature 72

Test 7 of 18

DIME Test ID: 2020-03-24-4-7
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1GUNC 5/8 0.2263152314013947313034729459A193 Rod
UTM 400kip
Temperature 72

Test 8 of 18

DIME Test ID: 2020-03-24-4-8
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1HUNC 5/8 0.2263141813913901712959829289A193 Rod
UTM 400kip
Temperature 72

Test 9 of 18

DIME Test ID: 2020-03-24-4-9
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A193 Rod
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1IUNC 5/8 0.2263167114014013013036329462A193 Rod
UTM 400kip
Temperature 72

Test 10 of 18

DIME Test ID: 2020-03-24-4-10
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .577 in
Pitch Diameter 2nd no data in

Test 11 of 18

DIME Test ID: 2020-03-24-4-11
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .578 in
Pitch Diameter 2nd no data in

Test 12 of 18

DIME Test ID: 2020-03-24-4-12
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .571 in
Pitch Diameter 2nd no data in

Test 13 of 18

DIME Test ID: 2020-03-24-4-13
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .571 in
Pitch Diameter 2nd no data in

Test 14 of 18

DIME Test ID: 2020-03-24-4-14
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .572 in
Pitch Diameter 2nd no data in

Test 15 of 18

DIME Test ID: 2020-03-24-4-15
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1F
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .572 in
Pitch Diameter 2nd no data in

Test 16 of 18

DIME Test ID: 2020-03-24-4-16
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1G
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .573 in
Pitch Diameter 2nd no data in

Test 17 of 18

DIME Test ID: 2020-03-24-4-17
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1H
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .571 in
Pitch Diameter 2nd no data in

Test 18 of 18

DIME Test ID: 2020-03-24-4-18
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/13/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1I
Rocap Number no data
Heat Number(s) 10610630
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .625 in
Bolt Length 12 in
Pitch Diameter .569 in
Pitch Diameter 2nd no data in

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.