Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210037 DEA: 043G4424 EFIS: 0412000042
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-R5.6/7.6
Work Description: WEST SPAN DAMPER BRACKET A325 BOLT TESTING
Location Description: SFOBB WEST SPAN
Contractor Name: CALIFORNIA ENGINEERING CONTRACTORS, INC.
Contractor Address: 20 Happy Valley Road, Pleasanton, CA 94566
Resident Engineer: Tom Larwin Structure Rep.: Sergio Gomez
DIME Sample ID: 2020-04-01-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/01/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2020
The quantity of what the sample constitutes: 310 ea
A brief description of the sample: A325 Fasteners
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name: SFOBB
The fabricator/manufacturer/facility name: Bay Bolt
Rocap Number(s): 1188-01
Heat Number(s): bolt-10629590
washer- 163050
nut- DL18104889
Nut Mfg. Lot Number(s): Nut- 416921B
Washer Mfg. Lot Number(s): Washer- 141843
Bolt Specification: A325
Bolt Length(s): 3 1/2"
Nut Specification: F563
Washer Specification: F436
Finish: Galv
Diameter/Size: 1"
Bolt Mfg. Lot Number: L569M1
Rocap Test Requirement(s): yes
Lubricant Requirements(s): yes
DIME Test ID: 2020-04-01-3-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 04/09/2020
Date Tested: 04/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Bolt
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1 | L569M1 | 1.0000 | 90989 | 404.74 | 10.00 | A325 Bolt | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2020-04-01-3-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 04/09/2020
Date Tested: 04/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 2 | L569M1 | 1.0000 | 90221 | 401.32 | 10.00 | A325 Nut | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2020-04-01-3-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 04/09/2020
Date Tested: 04/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A563 DH Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1 | 416921B | | 94361 | | A563 DH Nut | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-04-01-3-4
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 04/09/2020
Date Tested: 04/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A563 DH Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 2 | 416921B | | 94505 | | A563 DH Nut | fsaylor |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-04-01-3-5
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
.924 in
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2020-04-01-3-6
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
.929 in
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2020-04-01-3-7
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
.931 in
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2020-04-01-3-8
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
.937 in
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2020-04-01-3-9
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Pitch Diameter
|
.932 in
|
Pitch Diameter 2nd
|
no data in
|
DIME Test ID: 2020-04-01-3-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
3.02 mils
|
DIME Test ID: 2020-04-01-3-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
2.56 mils
|
DIME Test ID: 2020-04-01-3-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
3.43 mils
|
DIME Test ID: 2020-04-01-3-13
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
3.67 mils
|
DIME Test ID: 2020-04-01-3-14
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
L569M1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
LE USA A325
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
3.45 mils
|
DIME Test ID: 2020-04-01-3-15
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416921B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.0 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.36 mils
|
DIME Test ID: 2020-04-01-3-16
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416921B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.0 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.15 mils
|
DIME Test ID: 2020-04-01-3-17
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416921B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.0 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.08 mils
|
DIME Test ID: 2020-04-01-3-18
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416921B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.0 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.09 mils
|
DIME Test ID: 2020-04-01-3-19
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416921B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.0 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.18 mils
|
DIME Test ID: 2020-04-01-3-20
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.24 mils
|
DIME Test ID: 2020-04-01-3-21
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.12 mils
|
DIME Test ID: 2020-04-01-3-22
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.32 mils
|
DIME Test ID: 2020-04-01-3-23
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.49 mils
|
DIME Test ID: 2020-04-01-3-24
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.15 mils
|
DIME Test ID: 2020-04-01-3-25
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
35.9
|
Spacing
|
Ok
|
DIME Test ID: 2020-04-01-3-26
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
37.25
|
Spacing
|
Ok
|
DIME Test ID: 2020-04-01-3-27
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
1188-01
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
141843
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
37.35
|
Spacing
|
Ok
|