Print Report | Back to Sample Detail

Sample Record for 2020-04-01-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-04-01-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/01/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/01/2020
The quantity of what the sample constitutes: 1,003
A brief description of the sample: 3/4" x 10-1/2" F1554 Grade 55-S1/A153/F2329 All Thread Chisel Point
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s):
Heat Number(s): 1201014406
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: F1554 Grade 55-S1 / A153 / F2329
Bolt Length(s): 10-1/2"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 120101440660
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 12

DIME Test ID: 2020-04-01-1-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Grade 55
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1UNC 3/4 0.33430030133897616951623218F1554 Grade 55
UTM 400kip
Temperature 72

Test 2 of 12

DIME Test ID: 2020-04-01-1-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Grade 55
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
2UNC 3/4 0.33429947133895546979623312F1554 Grade 55
UTM 400kip
Temperature 72

Test 3 of 12

DIME Test ID: 2020-04-01-1-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Pitch Diameter 0.680 in
Pitch Diameter 2nd no data in

Test 4 of 12

DIME Test ID: 2020-04-01-1-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1B
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Pitch Diameter 0.695 in
Pitch Diameter 2nd no data in

Test 5 of 12

DIME Test ID: 2020-04-01-1-5
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1C
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Pitch Diameter 0.696 in
Pitch Diameter 2nd no data in

Test 6 of 12

DIME Test ID: 2020-04-01-1-6
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1D
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Pitch Diameter 0.699 in
Pitch Diameter 2nd no data in

Test 7 of 12

DIME Test ID: 2020-04-01-1-7
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1E
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Pitch Diameter 0.697 in
Pitch Diameter 2nd no data in

Test 8 of 12

DIME Test ID: 2020-04-01-1-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Measurement Average 5.52 mils

Test 9 of 12

DIME Test ID: 2020-04-01-1-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1B
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Measurement Average 6.16 mils

Test 10 of 12

DIME Test ID: 2020-04-01-1-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1C
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Measurement Average 5.85 mils

Test 11 of 12

DIME Test ID: 2020-04-01-1-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1D
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Measurement Average 5.53 mils

Test 12 of 12

DIME Test ID: 2020-04-01-1-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/09/2020
Date Tested: 04/09/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1E
Rocap Number F1554
Heat Number(s) 120101440660
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size .750 in
Bolt Length 10.5 in
Measurement Average 8.08 mils

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.