Print Report | Back to Sample Detail

Sample Record for 2020-03-18-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-18-14
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/18/2020
Date that the sample was received by the laboratory/organization performing the testing: 03/26/2020
The quantity of what the sample constitutes: 3
A brief description of the sample: A325 Bolts
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JLK Industries

Material Information

Rocap Number(s):
Heat Number(s): 3086600
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325
Bolt Length(s): 3.75"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 1.5"
Bolt Mfg. Lot Number: 55860-1
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 8

DIME Test ID: 2020-03-18-14-1
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Pitch Diameter 1.365 in
Pitch Diameter 2nd 1.362 in

Test 2 of 8

DIME Test ID: 2020-03-18-14-2
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Pitch Diameter 1.411 in
Pitch Diameter 2nd 1.411 in

Test 3 of 8

DIME Test ID: 2020-03-18-14-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Pitch Diameter 1.392 in
Pitch Diameter 2nd 1.392 in

Test 4 of 8

DIME Test ID: 2020-03-18-14-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Measurement Average 3.18 mils

Test 5 of 8

DIME Test ID: 2020-03-18-14-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Measurement Average 5.46 mils

Test 6 of 8

DIME Test ID: 2020-03-18-14-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Measurement Average 4.12 mils

Test 7 of 8

DIME Test ID: 2020-03-18-14-7
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Hardness Reading Scale C Scale
Hardness Reading Average 20.8
Spacing Ok

Test 8 of 8

DIME Test ID: 2020-03-18-14-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/02/2020
Date Tested: 04/02/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 55860-1
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Hardness Reading Scale C Scale
Hardness Reading Average 18.62
Spacing Ok