Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-03-26-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/26/2020
Date that the sample was received by the laboratory/organization performing the testing: 03/30/2020
The quantity of what the sample constitutes: 20,250
A brief description of the sample: 1"-8 heavy hex nuts
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle
Rocap Number(s):
Heat Number(s): 6215177703
Nut Mfg. Lot Number(s): 32219-6215177703
Washer Mfg. Lot Number(s): N/A
Bolt Specification: N/A
Bolt Length(s): N/A
Nut Specification: ASTM A194-2H
Washer Specification: N/A
Finish: Galvanized
Diameter/Size: 1"
Bolt Mfg. Lot Number: N/A
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2020-03-26-12-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A194 Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1 | 32219-6215177703 | | 106343 | | A194 Nut | fsaylor |
| |
UTM
|
400kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-03-26-12-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A194 Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 2 | 32219-6215177703 | | 106550 | | A194 Nut | fsaylor |
| |
UTM
|
400kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-03-26-12-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A194 Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 3 | 32219-6215177703 | | 106617 | | A194 Nut | |
| |
UTM
|
400kip
|
Temperature
|
72 f
|
DIME Test ID: 2020-03-26-12-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.27 mils
|
DIME Test ID: 2020-03-26-12-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.78 mils
|
DIME Test ID: 2020-03-26-12-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.17 mils
|
DIME Test ID: 2020-03-26-12-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.87 mils
|
DIME Test ID: 2020-03-26-12-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.82 mils
|
DIME Test ID: 2020-03-26-12-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1F
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.85 mils
|
DIME Test ID: 2020-03-26-12-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/07/2020
Date Tested: 04/03/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1G
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
32219-6215177703
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
Product Markings
|
U 2H ZN
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.33 mils
|