Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213733 DEA: 051C85U4 EFIS: 0518000156
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-10.2/17.5
Work Description: Santa Cruz 1 CAPM and Bridge Rails
Location Description: SANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ FROM NORTH APTOS UNDERPASS TO JUNCTION ROUTE 9.
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 585 West Beach Street, Watsonville, CA 95076
Resident Engineer: Gareth Gill Structure Rep.: Unknown
DIME Sample ID: 2020-01-30-43
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 02/18/2020
The quantity of what the sample constitutes: JMF Renewal
A brief description of the sample: 12 boxes HMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Felton
DIME Test ID: 2020-01-30-43-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/13/2020
Date Tested: 03/06/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
1716.4 g
|
Corrected Asphalt Binder Content
|
5.35 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.58 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
1000 F
|
DIME Test ID: 2020-01-30-43-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 03/13/2020
Date Tested: 03/11/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.313
|
Bulk Specific Gravity 2
|
2.312
|
Bulk Specific Gravity 3
|
2.311
|
Average Bulk Specific Gravity
|
2.312
|
DIME Test ID: 2020-01-30-43-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/13/2020
Date Tested: 03/09/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.418
|
Theoretical maximum density at 25°C (77°F)
|
no data
|
DIME Test ID: 2020-01-30-43-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 03/13/2020
Date Tested: 03/09/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
4.3 %
|
Percent Air Voids 2
|
4.4 %
|
Percent Air Voids 3
|
4.4 %
|
Percent Air Voids Average
|
4.4 %
|
DIME Test ID: 2020-01-30-43-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 03/13/2020
Date Tested: 03/13/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
SI Units
|
Average Dry Tensile Strength
|
192 psi
|
Average Wet Tensile Strength
|
174 psi
|
Tensile Strength Ratio
|
90.6
|
DIME Test ID: 2020-01-30-43-6
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 03/13/2020
Date Tested: 03/06/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
15000
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
15000
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
2.39 mm
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
1.8 mm
|
Stripping Inflection Point (Wheel A)
|
>25000
|
Stripping Inflection Point (Wheel B)
|
>25000
|