Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2020-03-12-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/12/2020
Date that the sample was received by the laboratory/organization performing the testing: 03/19/2020
The quantity of what the sample constitutes: 2,240
A brief description of the sample: 2" F436/A153/F2329 Flat Washers
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS Lindon UT
Rocap Number(s):
Heat Number(s): 290404
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s): D7581
Bolt Specification: n/a
Bolt Length(s):
Nut Specification: n/a
Washer Specification: F436
Finish: HDG
Diameter/Size: 2"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2020-03-12-12-1
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.01 mils
|
DIME Test ID: 2020-03-12-12-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4 mils
|
DIME Test ID: 2020-03-12-12-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.7 mils
|
DIME Test ID: 2020-03-12-12-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.15 mils
|
DIME Test ID: 2020-03-12-12-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.26 mils
|
DIME Test ID: 2020-03-12-12-6
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
40.9
|
Spacing
|
Ok
|
DIME Test ID: 2020-03-12-12-7
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
41.6
|
Spacing
|
Ok
|
DIME Test ID: 2020-03-12-12-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/02/2020
Date Tested: 04/01/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D7581
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
P F436
|
Size
|
2 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
39.9
|
Spacing
|
Ok
|