Print Report | Back to Sample Detail

Sample Record for 2020-01-30-40

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209141 DEA: 07215954 EFIS: 0700001835 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-0.0/7.6
Work Description: WIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location Description: LOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Thang Ton Structure Rep.: Amare Tsagie

Sample Information

DIME Sample ID: 2020-01-30-40
TL Number from the TL Form: Unknown
Sample Submitted By Organization: G3 Quality, Inc. - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/31/2020
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: Set 5
Structure unique identifier: 00-0000
Structure name: Abut 2 Approach Slab
The fabricator/manufacturer/facility name: Jobsite

Material Information

The concrete mix design number: G3-15-STR-002
The truck number from where the sample was collected: Load 43
The batch plant ticket number from where the sample was collected: 0
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Set 5
A detailed description of where the material sample was collected: Floerence Bridge - Abutment 3
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 6

DIME Test ID: 2020-01-30-40-1
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/05/2020
Date Tested: 02/07/2020
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 2
Average Compressive Strength (to nearest 10) 3650 lb/in^2
Cylinder Age 7 days
Break Description of Cylinder 1 (if not 'cone') no data
Break Description of Cylinder 2 (if not 'cone') no data

Test 2 of 6

DIME Test ID: 2020-01-30-40-2
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/05/2020
Date Tested: 02/28/2020
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens 2
Average Compressive Strength (to nearest 10) 5050 lb/in^2
Cylinder Age 28 days
Break Description of Cylinder 1 (if not 'cone') no data
Break Description of Cylinder 2 (if not 'cone') no data

Test 3 of 6

DIME Test ID: 2020-01-30-40-3
Test Method: CTM 557-July 2012: Method of Test for Temperature of Freshly Mixed Portland Cement Concrete
Verified Date: 03/05/2020
Date Tested: 01/30/2020
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature of the freshly mixed concrete 65 F

Test 4 of 6

DIME Test ID: 2020-01-30-40-4
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 03/05/2020
Date Tested: 01/30/2020
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete 148.4 lb/ft^3
Volume of the concrete 0 yd^3
Cement content 0 lb/yd^3

Test 5 of 6

DIME Test ID: 2020-01-30-40-5
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 03/05/2020
Date Tested: 01/30/2020
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air Content 1.5 %

Test 6 of 6

DIME Test ID: 2020-01-30-40-6
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 03/05/2020
Date Tested: 01/30/2020
Submitted By Organization: G3 Quality, Inc. - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: (562) 321-9840
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Oops.. looks like no test results have been submitted for the test.