Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213551 DEA: 080K2934 EFIS: 0812000100
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-R36.8/R39.2
Work Description: PAVEMENT REHABILITATION AND CONTINUOUSLY REINFORCED CONCRETE PAVEMENT
Location Description: SAN BERNARDINO COUNTY IN YUCAIPA FROM 0.2 MILE WEST OF LIVE OAK CANYON ROAD TO COUNTY LINE ROAD UNDERCROSSING
Contractor Name: Coffman Specialties
Contractor Address: 9685 Via Excelencia, San Diego, CA 92126
Resident Engineer: Ezz Gayed Structure Rep.: Unknown
DIME Sample ID: 2020-02-12-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 02/12/2020
Date that the sample was received by the laboratory/organization performing the testing: 02/13/2020
The quantity of what the sample constitutes: 4 Beams
A brief description of the sample: Concrete beams
From where was the sample collected: Job Site
Laboratory sample identification: 10A1, 10A2, 10B1, 10B2
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coffman Specialties, Inc
The concrete mix design number: 1810-2
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: TT1
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: On Job Site at Concrete Truck
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2020-02-12-25-1
Test Method: CTM 523-July 2012: Method of Test for Flexural Strength of Concrete
Verified Date: 02/28/2020
Date Tested: 02/25/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is being used?
|
Third-Point Loading
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Modulus of rupture
|
610 psi
|
DIME Test ID: 2020-02-12-25-2
Test Method: CTM 523-July 2012: Method of Test for Flexural Strength of Concrete
Verified Date: 02/28/2020
Date Tested: 02/25/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is being used?
|
Third-Point Loading
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Modulus of rupture
|
600 psi
|
DIME Test ID: 2020-02-12-25-4
Test Method: CTM 523-July 2012: Method of Test for Flexural Strength of Concrete
Verified Date: 03/23/2020
Date Tested: 03/11/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is being used?
|
Third-Point Loading
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Modulus of rupture
|
800 psi
|
DIME Test ID: 2020-02-12-25-5
Test Method: CTM 523-July 2012: Method of Test for Flexural Strength of Concrete
Verified Date: 03/23/2020
Date Tested: 03/11/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is being used?
|
Third-Point Loading
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Modulus of rupture
|
760 psi
|