Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214276 DEA: 050N2004 EFIS: 0516000016
QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-101-86.0/95.8
Work Description: CONSTRUCT TRAFFIC MONITORING STATION SYSTEMS.
Location Description: MONTEREY COUNTY IN AND NEAR SALINAS AT VARIOUS LOCATIONS FROM 0.4 MILE NORTH OF AIRPORT BOULEVARD OVERCROSSING TO 0.3 MILE SOUTH OF SAN MIGUEL CANYON OVERCROSSING
Contractor Name: Sturgeon Electric
Contractor Address: 1022 Black Gold Road, Bakersfield, CA 93308
Resident Engineer: Rodger Johnson Structure Rep.: David Galarza
DIME Sample ID: 2020-02-14-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 02/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 02/19/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: Anchor Cable with Swaged Fitting and Stud
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Assembly Specialty Products
Reel Number: 9237466
Painter Name or ID: NA
Material Specification: ASTM A931
Size: 1/2 in
Wire Manufacturer: Wirerope Works
Material Collected to Test: New Reel
DIME Test ID: 2020-02-14-6-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 02/21/2020
Date Tested: 02/21/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok break
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
400kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
62473
|
Operator
|
NA
|
Location of Failure
|
Below Crimp
|