Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044G0564 Cty ALA Rte 680 PM M2.4/M12.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Yannaing Tun |
Date Reported: |
03/05/2020 |
|
Address: |
TL Number: |
196076 |
||
City: |
||||
Project Name: ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
||||
Prime Contractor: BAY CITIES PAVING & GRADING, INC. |
||||
Sample Taken Date: |
02/06/2020 |
Mix Design: |
D201C5E1 |
|
Contractor: Unknown |
Location : FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.03 | 28.54 | 132942 | 4658.1 | 1 |
2 | 6.03 | 28.54 | 141118 | 4944.6 | 1 |
DIME Test ID: 2020-02-06-17-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4800
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing