Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212988 DEA: 080R1604 EFIS: 0812000029
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R50.0/R75.0
Work Description: REGRADE MEDIAN CROSS SLOPES
Location Description: NEAR LUDLOW FROM 0.3 MILES EAST OF CRUCERO ROAD TO 0.4 MILE WEST OF BADGER WASH
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEPE, AZ. 85284
Resident Engineer: Thanh Pham Structure Rep.: Leonard Romero
DIME Sample ID: 2020-02-04-4
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/04/2020
Date that the sample was received by the laboratory/organization performing the testing: 02/06/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 991-020420
Structure unique identifier:
Structure name: ds no 81
The fabricator/manufacturer/facility name: robertsons
The concrete mix design number: SC675B39
The truck number from where the sample was collected: na
The batch plant ticket number from where the sample was collected: na
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: fisher construction
A detailed description of where the material sample was collected: truck mixer chute
Where the material sample would have been placed if not sampled: ds no 81
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2020-02-04-4-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 02/11/2020
Date Tested: 02/11/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength (to nearest 10 psi)
|
4340 psi
|
Average diameter of cylinder 1
|
6.01 in
|
Average diameter of cylinder 2
|
6.01 in
|
Compressive strength of cylinder 1
|
4407.5 psi
|
Compressive strength of cylinder 2
|
4282.0 psi
|
Maximum load on cylinder 1
|
125040 lb
|
Maximum load on cylinder 2
|
121480 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
7 days
|