Print Report | Back to Sample Detail

Sample Record for 2020-01-27-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213856 DEA: 112888U4 EFIS: 1118000199 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-11,125,905-Various
Work Description: CONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY
Location Description: SAN DIEGO COUNTY AT VARIOUS LOCATIONS
Contractor Name: Skanska USA Civil West CA
Contractor Address: 1995 Agua Mansa Road, Riverside, CA 92509
Resident Engineer: Carlos Covarrubias Structure Rep.: Wade Durant

Sample Information

DIME Sample ID: 2020-01-27-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 01/27/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/31/2020
The quantity of what the sample constitutes: 4 samples from Lot # 1
A brief description of the sample: #14 ASTM 706 41'-4" Both Ends Headed Bar H55
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: S125/905 Connector
The fabricator/manufacturer/facility name: Integrity Rebar Placers

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 65021892
Head Manufacturer Lot Number(s): Lot 1
Rebar Size: 14
Headed Bar Model Name: NA
Size of Head: Full Size - 9x
Head Connection Type: Forged
Head Shape: Circular
Rebar Manufacturer: Gerdau
Head Manufacturer: Integrity Rebar Placers
Head Fabricator: Integrity Rebar Placers
Material Standard Code: ASTM A706
Headed Bar Unique ID:

Test Results

Test 1 of 3

DIME Test ID: 2020-01-27-17-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 01/29/2020
Date Tested: 01/29/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
12.2521586595940Ok neckingbewing
Temperature 72 f
UTM 400kip

Test 2 of 3

DIME Test ID: 2020-01-27-17-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 01/29/2020
Date Tested: 01/29/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
12.2521147493988Ok neckingbewing
Temperature 72 f
UTM 400kip

Test 3 of 3

DIME Test ID: 2020-01-27-17-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 01/29/2020
Date Tested: 01/29/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
12.2521339694843Ok neckingbewing
Temperature 72 f
UTM 400kip