Print Report | Back to Sample Detail

Sample Record for 2020-01-17-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214394 DEA: 101C8604 EFIS: 1016000023 QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-4-R16.8/R17.4
Work Description: REPAIR BRIDGE HINGE.
Location Description: SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF MADISION STREET TO 0.2 MILE WEST OF AIRPORTWAY UNDERCROSSING
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: 11315 SUNRISE GOLD CIR. #A, RANCHO CORDOVA CA 95742
Resident Engineer: David Abledu Structure Rep.: Daniel Laureno

Sample Information

DIME Sample ID: 2020-01-17-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/17/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/21/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: elastomeric bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 18508-1
Material/Compound/Elastomer ID: na
Samples Representing: 27
Description (size): 3.5x12x14
Comments: Unknown
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na

Test Results

Test 1 of 4

DIME Test ID: 2020-01-17-3-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 01/28/2020
Date Tested: 01/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 52
Reading #2 55
Reading #3 54
Reading #4 54
Reading #5 54
Mean 53.8

Test 2 of 4

DIME Test ID: 2020-01-17-3-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 01/28/2020
Date Tested: 01/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.07
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2705.29 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.07
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2725.3 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.07
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2721.21 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2721.2 lbf/in^2

Test 3 of 4

DIME Test ID: 2020-01-17-3-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 01/28/2020
Date Tested: 01/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.07
Sample 1 Tear Strength 219.2
Sample 2 Median Thickness 0.074
Sample 2 Tear Strength 218.8
Sample 3 Median Thickness 0.073
Sample 3 Tear Strength 217.6
Median of the Tear Strength Values 218.8 lb/in

Test 4 of 4

DIME Test ID: 2020-01-17-3-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 01/24/2020
Date Tested: 01/24/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass