Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214394 DEA: 101C8604 EFIS: 1016000023
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-4-R16.8/R17.4
Work Description: REPAIR BRIDGE HINGE.
Location Description: SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF MADISION STREET TO 0.2 MILE WEST OF AIRPORTWAY UNDERCROSSING
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: 11315 SUNRISE GOLD CIR. #A, RANCHO CORDOVA CA 95742
Resident Engineer: David Abledu Structure Rep.: Daniel Laureno
DIME Sample ID: 2020-01-17-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/17/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/21/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: elastomeric bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Mfg. Lot Number(s): 18508-1
Material/Compound/Elastomer ID: na
Samples Representing: 27
Description (size): 3.5x12x14
Comments: Unknown
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na
DIME Test ID: 2020-01-17-3-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 01/28/2020
Date Tested: 01/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
52
|
Reading #2
|
55
|
Reading #3
|
54
|
Reading #4
|
54
|
Reading #5
|
54
|
Mean
|
53.8
|
DIME Test ID: 2020-01-17-3-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 01/28/2020
Date Tested: 01/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.07
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2705.29 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.07
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2725.3 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.07
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2721.21 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2721.2 lbf/in^2
|
DIME Test ID: 2020-01-17-3-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 01/28/2020
Date Tested: 01/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.07
|
Sample 1 Tear Strength
|
219.2
|
Sample 2 Median Thickness
|
0.074
|
Sample 2 Tear Strength
|
218.8
|
Sample 3 Median Thickness
|
0.073
|
Sample 3 Tear Strength
|
217.6
|
Median of the Tear Strength Values
|
218.8 lb/in
|
DIME Test ID: 2020-01-17-3-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 01/24/2020
Date Tested: 01/24/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies