Print Report | Back to Sample Detail

Sample Record for 2020-01-17-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214392 DEA: 100H4804 EFIS: 1012000193 QA Service Level: 1
DIST-CO-RTE-PM: 10-STA-108-33.1/33.4
Work Description: COLD PLANE AC SURFACING, HMA (TYPE A) RESURFACING, AND BRIDGE REPAIR.
Location Description: STANISLAUS COUNTY IN RIVERBANK FROM 0.1 MILE WEST OF EIGHTH STREET TO 0.1 MILE EAST OF CLAUS ROAD
Contractor Name: VIKING CONSTRUCTION COMPANY, INC.
Contractor Address: P.O. Box 1508, Rancho Cordova, CA 95741
Resident Engineer: WALI WAZIRI Structure Rep.: George Samuel

Sample Information

DIME Sample ID: 2020-01-17-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/17/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/21/2020
The quantity of what the sample constitutes: 1
A brief description of the sample: elastomeric bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 18496-1
Material/Compound/Elastomer ID: na
Samples Representing: 7
Description (size): 3x10x12
Comments: Unknown
Description (Number of Shims): 6
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na

Test Results

Test 1 of 4

DIME Test ID: 2020-01-17-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 01/28/2020
Date Tested: 01/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 52
Reading #2 53
Reading #3 51
Reading #4 51
Reading #5 54
Mean 52.2

Test 2 of 4

DIME Test ID: 2020-01-17-2-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 01/28/2020
Date Tested: 01/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.075
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2636.97 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.072
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2671.04 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.075
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2672.36 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2671 lbf/in^2

Test 3 of 4

DIME Test ID: 2020-01-17-2-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 01/28/2020
Date Tested: 01/23/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.08
Sample 1 Tear Strength 208.2
Sample 2 Median Thickness 0.076
Sample 2 Tear Strength 209.5
Sample 3 Median Thickness 0.076
Sample 3 Tear Strength 203.5
Median of the Tear Strength Values 208.2 lb/in

Test 4 of 4

DIME Test ID: 2020-01-17-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 01/24/2020
Date Tested: 01/24/2020
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass