Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-12-23-13
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Control
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 12/23/2019
Date that the sample was received by the laboratory/organization performing the testing: 01/07/2020
The quantity of what the sample constitutes: 5
A brief description of the sample: Wire Rope
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Oakland Caltrans paint Crew
Reel Number: Unknown
Painter Name or ID: S146551, S146193, S146194, S146552, S146080
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer: Unknown
Material Collected to Test: Operator
DIME Test ID: 2019-12-23-13-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 01/08/2020
Date Tested: 01/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope choker 5/16
|
Peak Load
|
10410.9
|
Operator
|
Ahmed Yusaf 146551
|
Location of Failure
|
At Crimp
|
DIME Test ID: 2019-12-23-13-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 01/08/2020
Date Tested: 01/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10413.7
|
Operator
|
Shelby Wesson 146194
|
Location of Failure
|
Below Crimp
|
DIME Test ID: 2019-12-23-13-3
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 01/08/2020
Date Tested: 01/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10621.8
|
Operator
|
Robert Holt 146193
|
Location of Failure
|
Below Crimp
|
DIME Test ID: 2019-12-23-13-4
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 01/08/2020
Date Tested: 01/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10838.6
|
Operator
|
Arriama Pyne 146552
|
Location of Failure
|
Below Crimp
|
DIME Test ID: 2019-12-23-13-5
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 01/08/2020
Date Tested: 01/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Wire Rope
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 F
|
UTM
|
67kip
|
Specimen Identification
|
Wire Rope
|
Peak Load
|
10363.9
|
Operator
|
Majesty Edwards146080
|
Location of Failure
|
At Crimp
|