Sample Record for 2019-10-04-9
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211260 DEA: 072159U4 EFIS: 0715000160
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work Description: CONSTRUCT HOV LANES AND MIX FLOW LANES.
Location Description: LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 TOWNSGATE RD. SUITE 200, WESTLAKE VILLAGE, CA 91361
Resident Engineer: George Saker Structure Rep.: Danny Lalonde
Sample Information
DIME Sample ID: 2019-10-04-9
TL Number from the TL Form: Unknown
Sample Submitted By Organization: G3 Quality, Incorporated - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/04/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/04/2019
The quantity of what the sample constitutes: 10
A brief description of the sample: 6X12 Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: Set 1
Structure unique identifier: 00-0000
Structure name: Unknown
The fabricator/manufacturer/facility name: Volumetric
Material Information
The concrete mix design number: CTS-1-14
The truck number from where the sample was collected: Load 1
The batch plant ticket number from where the sample was collected: 0
Concrete batch plant: Security Paving
The fabricator/manufacturer designation for the sample: Set 1
A detailed description of where the material sample was collected: North Side of Bridge, STA 53-3045
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 9
DIME Test ID: 2019-10-04-9-1
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/02/2019
Date Tested: 10/04/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test: 4 hours break
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
2
|
Average Compressive Strength (to nearest 10)
|
3330 lb/in^2
|
Cylinder Age
|
no data0 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 2 of 9
DIME Test ID: 2019-10-04-9-2
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/02/2019
Date Tested: 10/07/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
2
|
Average Compressive Strength (to nearest 10)
|
5640 lb/in^2
|
Cylinder Age
|
3 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 3 of 9
DIME Test ID: 2019-10-04-9-3
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/02/2019
Date Tested: 10/08/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
2
|
Average Compressive Strength (to nearest 10)
|
5930 lb/in^2
|
Cylinder Age
|
4 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 4 of 9
DIME Test ID: 2019-10-04-9-4
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/02/2019
Date Tested: 10/11/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
2
|
Average Compressive Strength (to nearest 10)
|
5860 lb/in^2
|
Cylinder Age
|
7 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 5 of 9
DIME Test ID: 2019-10-04-9-5
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/02/2019
Date Tested: 11/01/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
2
|
Average Compressive Strength (to nearest 10)
|
7050 lb/in^2
|
Cylinder Age
|
28 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 6 of 9
DIME Test ID: 2019-10-04-9-6
Test Method: CTM 557-July 2012: Method of Test for Temperature of Freshly Mixed Portland Cement Concrete
Verified Date: 12/02/2019
Date Tested: 10/04/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature of the freshly mixed concrete
|
71 F
|
Test 7 of 9
DIME Test ID: 2019-10-04-9-7
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 12/02/2019
Date Tested: 10/04/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete
|
146.82 lb/ft^3
|
Cement content
|
no data0 lb/yd^3
|
Test 8 of 9
DIME Test ID: 2019-10-04-9-8
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 12/02/2019
Date Tested: 10/04/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 9 of 9
DIME Test ID: 2019-10-04-9-9
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 12/02/2019
Date Tested: 10/04/2019
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Ball penetration in freshly mixed concrete (average)
|
2.5 inch
|