Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 7780 DEA: 112T1824 EFIS: 1100020051
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Tom Davis Structure Rep.: Anh Ma
DIME Sample ID: 2013-08-20-9308691
TL Number from the TL Form:
Sample Submitted By Organization: Signet Testing Laboratories - Anaheim
Sample Organization Contact: (714) 399-1500
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/20/2013
Date that the sample was received by the laboratory/organization performing the testing: 08/21/2013
The quantity of what the sample constitutes: 4 cylinders
A brief description of the sample: Set 2
From where was the sample collected: Source
Laboratory sample identification: 2013-08-20-0930
Structure unique identifier: 311RW
Structure name: Sound Barrier Wall
The fabricator/manufacturer/facility name: Vulcan
The concrete mix design number: 103612F
The truck number from where the sample was collected: 394
The batch plant ticket number from where the sample was collected: 147811
Concrete batch plant:
The fabricator/manufacturer designation for the sample: Vulcan / 103612F
A detailed description of where the material sample was collected: Sound Wall
Where the material sample would have been placed if not sampled: Sound Wall
From Lot No.:
Bag Lot No.:
DIME Test ID: 2013-08-20-9308691-1
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 09/04/2013
Date Tested: 09/03/2013
Submitted By Organization: Signet Testing Laboratories - Anaheim
Organization Address: 1320 Simpson Circle,
Organization City: Anaheim
Organization State: CA
Organization Zipcode: 92806
Organization Email:
Organization Phone: (714) 399-1500
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample
|
Set 2
|
Volume of the measure
|
0.25 ft^3
|
Density of concrete
|
146 lb/ft^3
|
Yield of concrete
|
no data
|
Relative yield of the batch
|
no data
|
Cement content
|
no data
|
Air content
|
1.6 %
|
DIME Test ID: 2013-08-20-9308691-2
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 09/04/2013
Date Tested: 09/03/2013
Submitted By Organization: Signet Testing Laboratories - Anaheim
Organization Address: 1320 Simpson Circle,
Organization City: Anaheim
Organization State: CA
Organization Zipcode: 92806
Organization Email:
Organization Phone: (714) 399-1500
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2013-08-20-9308691-3
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 09/04/2013
Date Tested: 09/03/2013
Submitted By Organization: Signet Testing Laboratories - Anaheim
Organization Address: 1320 Simpson Circle,
Organization City: Anaheim
Organization State: CA
Organization Zipcode: 92806
Organization Email:
Organization Phone: (714) 399-1500
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2013-08-20-9308691-4
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/04/2013
Date Tested: 09/03/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test: ticket 147811
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
no data
|
Cylinder Age
|
14 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
DIME Test ID: 2013-08-20-9308691-5
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 10/04/2013
Date Tested: 10/01/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test: ticket 147811
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
no data
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
DIME Test ID: 2013-08-20-9308691-6
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/18/2013
Date Tested: 10/15/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
no data
|
Cylinder Age
|
56 days
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|