Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-11-20-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Recertification
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 11/20/2019
Date that the sample was received by the laboratory/organization performing the testing: 11/26/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: 1-1/4" x 18"
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Simplex JC Supply
Dowel Metal Heat Number: 190332
Dowel Epoxy Batch Number: 3CH1933053
Dowel Coating Specification: ASTM A775
Dowel Size: 1.25 in
Dowel Coating Color: Green
Dowel Manufacturer: ASI
Dowel Coater: Simplex JC Supply
Release Number: N/A
Quality Assurance Code: N/A
Rebar Size (#): N/A
DIME Test ID: 2019-11-20-1-1
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 11/27/2019
Date Tested: 11/26/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
9.66 mils
|
Second Bar Mean
|
9.25 mils
|
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
40 mils
|
Total mean value
|
9.46 mils
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-11-20-1-2
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 11/27/2019
Date Tested: 11/26/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
1
|
Total Length
|
3
|
Holidays Per Linear Foot of Bar
|
0.3
|
Holiday Test Pass/Fail
|
Pass
|