REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Iqbal Aulakh |
Date Reported: |
12/05/2019 |
|
Address: |
TL Number: |
1019000196 |
||
City: |
||||
Project Name: |
||||
Prime Contractor: Q&D Construction Inc. |
||||
Sample Taken Date: |
11/07/2019 |
Mix Design: |
000000000 |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.00 | 28.26 | 93316 | 3302.1 | 1 |
2 | 6.00 | 28.26 | 100800 | 3566.9 | 1 |
DIME Test ID: 2019-11-07-5-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3430
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |