Print Report | Back to Sample Detail

Sample Record for 2019-11-12-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-11-12-5
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Retest
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2019
The quantity of what the sample constitutes: 10
A brief description of the sample: 3/4" x 10-1/2" ASTM F1554 Grade 55-S1 F2329 All Thread Rod Chisel Point
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s):
Heat Number(s): DL19102203
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM F1554 Grade 55-S1 / A153 / F2329
Bolt Length(s): 10-1/2"
Nut Specification: n/a
Washer Specification: n/a
Finish: Galvanized
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 47298-PPO
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 15

DIME Test ID: 2019-11-12-5-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Tensile
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1AUNC 3/4 0.33432229143964948530528492F1554 Tensile
UTM 400kip
Temperature 72

Test 2 of 15

DIME Test ID: 2019-11-12-5-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Tensile
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1BUNC 3/4 0.33432377144968908533728503F1554 Tensile
UTM 400kip
Temperature 72

Test 3 of 15

DIME Test ID: 2019-11-12-5-3
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Tensile
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1CUNC 3/4 0.33432300143966598503728402F1554 Tensile
UTM 400kip
Temperature 72

Test 4 of 15

DIME Test ID: 2019-11-12-5-4
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Tensile
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1DUNC 3/4 0.33432249143965548483128334F1554 Tensile
UTM 400kip
Temperature 72

Test 5 of 15

DIME Test ID: 2019-11-12-5-5
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Tensile
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1EUNC 3/4 0.33432236143964568477428315F1554 Tensile
UTM 400kip
Temperature 72

Test 6 of 15

DIME Test ID: 2019-11-12-5-6
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Gage Type Pass

Test 7 of 15

DIME Test ID: 2019-11-12-5-7
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Gage Type Pass

Test 8 of 15

DIME Test ID: 2019-11-12-5-8
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Gage Type Pass

Test 9 of 15

DIME Test ID: 2019-11-12-5-9
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Gage Type Pass

Test 10 of 15

DIME Test ID: 2019-11-12-5-10
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Gage Type Pass

Test 11 of 15

DIME Test ID: 2019-11-12-5-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Measurement Average 5.64 mils

Test 12 of 15

DIME Test ID: 2019-11-12-5-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Measurement Average 6.55 mils

Test 13 of 15

DIME Test ID: 2019-11-12-5-13
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Measurement Average 6.75 mils

Test 14 of 15

DIME Test ID: 2019-11-12-5-14
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Measurement Average 6.74 mils

Test 15 of 15

DIME Test ID: 2019-11-12-5-15
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/20/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) DL19102203
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size .75 in
Bolt Length 10.5 in
Measurement Average 5.44 mils

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.