Print Report | Back to Sample Detail

Sample Record for 2019-11-12-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-11-12-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Stock
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2019
The quantity of what the sample constitutes: 5
A brief description of the sample: ASTM A563 Grade A Coupling Nuts
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle Corp

Material Information

Rocap Number(s): NA
Heat Number(s): 100897024
Nut Mfg. Lot Number(s): 904635
Washer Mfg. Lot Number(s): NA
Bolt Specification: NA
Bolt Length(s): NA
Nut Specification: ASTM A563 Grade A
Washer Specification: NA
Finish: HDG
Diameter/Size: 3/4" -10 x 2-1/4" - 1-1/4"
Bolt Mfg. Lot Number: NA
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA

Test Results

Test 1 of 8

DIME Test ID: 2019-11-12-4-1
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Measurement Average 2.97 mils

Test 2 of 8

DIME Test ID: 2019-11-12-4-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Measurement Average 3.06 mils

Test 3 of 8

DIME Test ID: 2019-11-12-4-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Measurement Average 3.37 mils

Test 4 of 8

DIME Test ID: 2019-11-12-4-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Measurement Average 3.62 mils

Test 5 of 8

DIME Test ID: 2019-11-12-4-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Measurement Average 3.06 mils

Test 6 of 8

DIME Test ID: 2019-11-12-4-6
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Hardness Reading Scale B Scale
Hardness Reading Average 90.65
Spacing Ok

Test 7 of 8

DIME Test ID: 2019-11-12-4-7
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Hardness Reading Scale B Scale
Hardness Reading Average 89.92
Spacing Ok

Test 8 of 8

DIME Test ID: 2019-11-12-4-8
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/21/2019
Date Tested: 11/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 100897024
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings no data
Size .75 in
Bolt Length no data in
Hardness Reading Scale B Scale
Hardness Reading Average 89.15
Spacing Ok