Print Report | Back to Sample Detail

Sample Record for 2019-10-15-18

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214111 DEA: 081J5604 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15,74,79-VAR.
Work Description: REPLACE AC SURFACING AND PLACE RHMA-G.
Location Description: RIVERSIDE COUNTY AT VARIOUS LOCATIONS
Contractor Name: All American Asphalt
Contractor Address: 400 E. 6th St., Corona, CA 92879
Resident Engineer: Mike Bergevin Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-10-15-18
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/15/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/21/2019
The quantity of what the sample constitutes: 2 box, 3 Core
A brief description of the sample: HMA 3/4" PG 64-28
From where was the sample collected: Manufacturer
Laboratory sample identification: 9A, 9B, 9C
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: Unknown
Sublot number: Unknown
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2019-10-15-18-1
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/29/2019
Date Tested: 10/22/2019
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.365
Bulk Specific Gravity 2 2.391
Bulk Specific Gravity 3 2.403
Average Bulk Specific Gravity 2.386

Test 2 of 2

DIME Test ID: 2019-10-15-18-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/29/2019
Date Tested: 10/22/2019
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.495
Theoretical maximum density at 25°C (77°F) no data